The Wright Safety Company
Personal & Environmental Protective Products




GAS MASKS IN STOCK !

SDVOSB - Service Disabled Veteran Owned Small Business

 

Product Specifications: Advantage® 1000 CBA-RCA Gas Mask

 

The Advantage 1000 CBA-RCA Gas Masks from MSA are specifically designed for use by law enforcement and emergency response personnel.The facepiece features a single low-profile canister.The gas mask is NIOSH approved (No.TC-14G-0235) for protection against chloroacetphenone (CN),chlorobenzylidene (CS),P100 particulate efficiency level and particulates.The gas mask does not have NIOSH approval for oleoresin capsicum, the “active”ingredient of OC Tear Gas.The canister provides up to eight hours service time against CN,CS,and OC agents.  Please see the table bellow for additional information.  The Advantage 1000 CBA-RCA Gas Masks are also effective against biological agents,along with the following chemical warfare (CW) agents:GA,GB (Sarin),GD,VX, Mustard,and Lewisite.Testing conducted by MSA and independent laboratories assures that the gas mask and canister meet the requirements for effectiveness against CW agents using the test protocol recommended by the Chemical Agent Safety and Health Policy Action Committee (CASHPAC).They are also effective against OC (oleoresin capsicum) Riot Control Agent and HCN (hydrogen cyanide),but have not been tested or approved by NIOSH for these applications. Please see the table on page three for additional information.

 

Features:

  • Flexible, one piece polyurethane lens with wide field of vision, bonded to a durable super-soft Hycar rubber facepiece.
  • NIOSH approved for protection against CN and CS tear gas.
  • Effective against, but does not have approval for OC tear gas. • Is effective against biological agents and chemical warfare agents.
  • Dual-canister mount to allow weapon firing from either shoulder.

 

The Advantage 1000 CBA-RCA Gas Mask is a clean, simplified respirator with super-soft Hycar facepiece (based on a proven facepiece design developed for the U.S. Armed Forces) that’s up to 40% lighter than conventional full-face respirators and gives high performance, customized fit,comfort,economy and user acceptance.

The flexible,1-piece polyurethane lens has a wide field of vision and is bonded to a durable super-soft Hycar rubber facepiece. Bonding a flexible lens to the facepiece eliminates the need for a rigid lens that can cause uncomfortable pressure points.The facepiece has a wraparound design that minimizes dead-air space and provides good vision.The compact size also permits easy integration with most visored police helmets.

The facepiece has canister inlet ports on either side of the facepiece.  The canister position (bayonet mount) can be switched to enable the user to sight a weapon from either shoulder.  The Advantage 1000 CBA-RCA Gas Masks are molded of super-soft black Hycar rubber,a specially formulated combination of natural rubber and synthetic materials.The facepiece is soft and pliable for a snug,comfortable fit. Hycar resists chemical attack and temperature extremes, and is able to withstand rugged daily use.Hycar is particularly resistant to permeation against chemical warfare agents.The fully elastic,6-point head harness promotes easy on-off,easy adjustment,with no hair
pulling.

Standard equipment includes a speaking diaphragm for clear,short-range communications,or add MSA’s optional ESP Communication System.The facepiece also features a nosecup, to reduce lens fogging in low temperatures or high humidity conditions.

 

Test Results:

MSA’s Advantage 1000 CBA-RCA/Millennium Gas Mask Canister has been tested to determine how effectively it can protect an individual against a variety of chemical agents (in accordance with CASHPAC).  This canister contains a pleated high-efficiency (HEPA) filter to remove aerosols and solid particulates, and an impregnated activated carbon bed to adsorb (filter out) gases and liquid vapors.The HEPA filter removes nearly all of the tear gas agents from the inspired airstream. Any small amount of tear gas agent that passes through the filter is adsorbed by the impregnated activated carbon. Sarin (GB),DMMP (a Sarin simulant), and HCN are also effectively adsorbed by the carbon bed.  The challenge agents are listed in column 1; testing conditions and requirements in columns 2, 3, and 4; and test results in the last column.  The Flow Rate for all challenge agents was 64 ±1 Lpm, except for CK, which was 32 Lpm.Temperature was 25 ±3 degrees Centigrade.

 

Challenge Agent Challenge Concentration, mg/m3 Relative Humidity,% Minimum Service Time Requirement TEST RESULTS: Service Time until Break, in minutes
Dimethyl Methylphosphonate (DMMP)
(Sarin Simulant)
Nerve agent
1000 ±70 25 ±0.5 60 minutes until a 0.04 mg/m3 break >63
Sarin (GB)
Nerve agent
1000 ±70 25 ±0.5 60 minutes until a 0.04 mg/m3 break >70
Hydrogen Cyanide (AC)
Blood agent
550 ±25 50 ±3 30 minutes until a 5 mg/m3 break >40
HCN after Equilibration for 6 hours @
25% RH
550 ±25 50 ±3 30 minutes until a 5 mg/m3 break >40
HCN after Equilibration for 6 hours @
85% RH
550 ±25 50 ±3 30 minutes until a 5 mg/m3 break >40
ortho-Chlorobenzylidene Malononitrile
(CS) Tear Gas
Irritant
23 ±8 50 ±3 480 minutes until a 0.4 mg/m3 break >480
CS after Equilibration for 6 hours @ 25%
RH
23 ±8 25 ±3 480 minutes until a 0.4 mg/m3 break >480
CS after Equilibration for 6 hours @ 85%
RH
23 ±8 85 ±3 480 minutes until a 0.4 mg/m3 break >480
a Chloroacetophenone (CN) Tear Gas
Irritant
101 ±6 50 ±3 480 minutes until a 0.3 mg/m3 break >480
CN after Equilibration for 6 hours @ 25%
RH
101 ±6 25 ±3 480 minutes until a 0.3 mg/m3 break >480
CN after Equilibration for 6 hours @ 85%
RH
101 ±6 85 ±3 480 minutes until a 0.3 mg/m3 break >480
Oleoresin capsicum (C18H27NO3), the
“active” ingredient of the OC tear gas
Irritant
0.036 50 ±3 None >480 until a
0.001 mg/m3 break
Cyanogen Chloride (CK)
Blood agent
Approx. 4000 80 None 5 to 9 until an
8 mg/m3 break
Note 1. CK testing was performed according to Mil-C-51560 by Edgewood Arsenal.
Note 2. GB testing was performed by TNO Netherlands.

 

 

 

 

Home   |  FAQs  |  Terms of Use  |  Privacy Contact Us

3842 Congress Parkway • Richfield, OH 44286 • Phone: 877-948-2000 • Fax: 800-948-7233